TRISTAR
PRIME CONTRACTING LLC
EXPLORE THE PLATFORM BELOW
01 / WHAT’S ONBOARD
24/7 Water Production System
A purpose-built mobile platform brings water generation, onboard storage and multiple power sources together in one truck.
01 / MOBILITY

Heavy-duty chassis
Ford F-750 DRW platform.
02 / ENERGY

Power bay
48 kWh battery, 25–30 kW three-phase inverter/charger
03 / GENERATION

Atmospheric Water Generator
Up to 360/gal production per day
04 / STORAGE

Water storage
300–400 gallons of baffled potable-water storage.
05 / DIESEL POWER

Diesel Generator
30 kW, 1,800-RPM diesel genset in an acoustic enclosure.
06 / SOLAR POWER

Rooftop solar
3.5 kW rooftop PV array
07 / SHORE POWER

External power
208/230 V three-phase shore-power input.
08 / SYSTEM CONTROL

Monitoring & control
Automatic generator start/stop based on battery state of charge. Remote telemetry for water production, energy use, fuel, battery state of charge and system health.
02 / THE COMPLETE PLATFORM
One Platform, One Mission : Water from Air
ENERGY SYSTEM / POWER ARCHITECTURE
Designed for continuous operation.
Solar, battery storage and backup power work together to support 24/7 off-grid, mobile water generation.
01 / SOLAR
3.5 kW PV
MPPT / DC bus
02 / BATTERY
60 kWh
Approximately 48kWh
03 / INVERTER / CHARGER
25–30 kW
Three-phase output
04 / AWG
208/230 V
Up to 360 gal/day
BACKUP INPUT TO INVERTER / CHARGER
30 kW diesel genset
1,800 RPM / automatic start
EXTERNAL INPUT TO INVERTER / CHARGER
Shore power
208/230 V three-phase
POWER PRIORITY: SOLAR / BATTERY BUFFER / AUTO-GENSET BACKUP
DESIGN ENERGY BALANCE
MAXIMUM PUBLISHED PRODUCTION
360 gal/day
Maximum published water output
PUBLISHED CONSUMPTION
0.60 kWh/gal
At 90°F / 90% relative humidity
DAILY ENERGY REQUIREMENT
~216 kWh/day
At maximum production
EQUIVALENT AVERAGE DEMAND
~9 kW
T-200 average demand
The 30 kW genset provides sufficient capacity to operate the T-200 while simultaneously recharging the 120 kWh battery. Production and consumption figures below are published design values, not guaranteed output in all conditions.
OPERATING PROFILE / 24 HOURS
Continuous Water Production. Day or Night.
An illustrative energy contribution profile, from morning solar to automated overnight backup.
SOLAR
BATTERY
GENERATOR
06:00
18:00
06:00
06:00–11:00
Morning solar + battery
Solar production ramps up while the battery supplements AWG demand.
11:00–16:00
Peak solar
Solar can offset approximately 50–65% of instantaneous AWG demand during strong peak-sun conditions. The battery supplies the balance.
16:00–22:00
Evening battery run
Battery supports quiet T-200 operation using stored energy.
22:00–06:00
Automated genset cycle
Generator operates approximately 8–9 hours/day as required by battery state of charge, solar availability and production demand.
Generator + battery: the generator simultaneously powers the AWG while excess capacity recharges the battery. The schedule is illustrative; actual generator runtime and solar contribution vary with temperature, humidity, solar irradiance, battery state of charge and desired production rate.
03 / START A CONVERSATION
Let’s talk about your mission.
Connect with Tristar to discuss the mobile atmospheric water generation platform and your operational requirements.
REQUEST A CONSULTATION

CONCEPT DESIGN / PRELIMINARY SPECIFICATIONS. Final configuration is subject to engineering review. Specifications shown follow the integrated subsystem breakdown; the source collage depicts alternate component labels.